All electrical installations are tested either when a Electrician carries out any work such as new circuits or rewires or an existing electrical installation is tested at regular intervals to ensure that the installation complies with regulations and has no defects that could cause fires or electric shocks.
Existing circuits that are regularly tested is known as EICR (Electrical Installation Condition Reports) or previously known as PIR (Periodic Inspection Report).
All electrical installations whether it is Domestic , Commercial or Industrial deteriorate with age and usage.
The electrician will carry out the appropriate tests and inspect every circuit in the fuse board and a sample of all your accessories (i.e switches, sockets etc) to ascertain the condition of the installation and identify any defects against the current wiring regulations.The electrician must ensure that all necessary precautions are being taken to reduce the risk of injury or death through electrical failure.
There are many good reasons for having an Electrical Installation Condition Report (EICR).If you have recently acquired ownership or tenancy of business / workplace premises you may wish to ensure the installation is safe by having it inspected.
The inspecting electrician will carry out a sequence of tests such as:
Earth continuity - to ascertain that the earthing is continuous throughout the circuits
Earth Bonding - checking that you main water and gas pipes are earthed with the correct earthing conductor size
Insulation resistance - this is to check any breakdown of insulation in the installation
RCD testing - to ascertain that the RCD will disconnect the supply in case of a fault
A test on your main earthing and or earth rod
Functional testing of isolators, switches and MCBs - to ascertain they isolate the supply
The time intervals between the inspections are recommended as follows:
Home owner - either change of occupancy/ or inspect every 10 years (can be more frequent if you are concerned about the safety of your electrical installation)
Rented accommodation - either change of occupancy / or inspect every 5 years
Commercial - either change of occupancy / or inspect every 5 years
If the installation is in a safe condition you will receive a satisfactory condition report which may include any findings that deviates for current regulations, but does not effect your safety.This is noted as C3
C3 codes are recommendations to improve your installation or bring it up to current regulations. A C3 code is an advisory and does not effect the safety of the installation
However, if you electrical installation is found to be unsatisfactory (failed) you will be given a copy of the unsatisfactory certificate including a list of defects either coded C1 (dangerous condition), C2 (potentially dangerous condition) and/ or FI (a in depth further investigation).
With these unsatisfactory codes you could be given a quote to carry out remedial works to bring your installation to a satisfactory condition
Your local electrician - Bristol
Get in touch :
call 0117 321 6406
Use our online enquiry form :
Social Media :
!! Take Care When Selecting an Electrician !!
Many electricians in Bristol are simply not interested in the small jobs.They want the choice jobs and will drop you when a bigger,supposedly more lucrative project comes in.
Others advertise as electricians having no qualifications.They thrive on the basis that you don't understand what they do and as a result charging for shoddy,and often dangerous electrical work.
I set up Burridge Electrical to provide you with a quality service and provide you with exactly what you need from a qualified electrician.
Your Trusted Local Electrician
Burridge Electrical - Electrician covering Bristol and the surrounding area